The heating of this incubator is optimally tuned for both natural convection and forced air circulation; the fan can also be switched off completely, and valuable chamber loads for research, pharmaceutics, medicine and food chemistry are warmed up very carefully.
Working temperature range: min. 10°C above ambient up to +80°C.
Setting accuracy temperature: 0.1°C.
Temperature: 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
Language setting: German, English, Spanish, French, Polish, Czech, Hungarian
ControlCOCKPIT: TwinDISPLAY. adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT- colour displays
Timer: Digital backwards counter with target time setting, adjustable from 1 minute to 99 days
Function SetpointWAIT: the process time does not start until the set temperature is reached
Calibration: three freely selectable temperature values
adjustable parameters: temperature (Celsius or Fahrenheit), fan speed, air flap position, programme time, time zones, summertime/wintertime
Sterilisation: fixed sterilisation programme (4 hours/160°C) for sterilisation of working chamber, not for sterilising the load.
Fan: forced air circulation by quiet air turbine, adjustable in 10 % steps for each segment individually
Fresh air admixture: adjustment of pre-heated fresh air admixture by air flap control in 10 % steps for each segment individually.
Vent: vent connection with restrictor flap.
Temperature control: mechanical temperature limiter TB, protection class 1 according to DIN 12880 to switch off the heating approx. 20°C above nominal temperature
Temperature control: overtemperature monitor TWW, protection class 3.1 or adjustable temperature limiter TWB, protection class 2, selectable on display
AutoSAFETY: additionally integrated over- and undertemperature monitor "ASF", automatically following the setpoint value at a preset tolerance range, alarm in case of over- or undertemperature, heating is switched off in case of overtemperature.
Autodiagnostic system: for fault analysis.
Alarm: visual and acoustic.
Untuk informasi lebih lanjut, silahkan hubungi :
Distributor, Agent, Penjualan, Pemasangan dan Training. Jakarta - Indonesia, PT. Anugrah Niaga Mandiri.
Hubungi Kami :
Irfan ( 0816 1337 337 ) , ( 081317103376 ). : Tia ( 081617408900 ).
Alamat : Jl.Radin Inten II No.61 A, Duren Sawit, Jakarta Timur.
Telp : + 62-21 8690 6782, + 62-21 8690 6783.
Fax : + 62-21 8690 6781.
Email : sales@anm.co.id.
Website : www.anm.co.id.